{"id":1417,"date":"2026-04-02T15:29:30","date_gmt":"2026-04-02T07:29:30","guid":{"rendered":"https:\/\/glowinled.com\/?p=1417"},"modified":"2026-03-30T15:43:23","modified_gmt":"2026-03-30T07:43:23","slug":"how-to-verify-lm-80-reports-for-led-strips","status":"publish","type":"post","link":"https:\/\/glowinled.com\/ru\/how-to-verify-lm-80-reports-for-led-strips\/","title":{"rendered":"\u041a\u0430\u043a \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043e\u0442\u0447\u0451\u0442\u044b LM-80 \u0434\u043b\u044f \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u043b\u0435\u043d\u0442?"},"content":{"rendered":"<style>article img, .entry-content img, .post-content img, .wp-block-image img, figure img, p img {max-width:100% !important; height:auto !important;}figure { max-width:100%; }img.top-image-square {width:280px; height:280px; object-fit:cover;border-radius:12px; box-shadow:0 2px 12px rgba(0,0,0,0.10);}@media (max-width:600px) {img.top-image-square { width:100%; height:auto; max-height:300px; }p:has(> img.top-image-square) { float:none !important; margin:0 auto 15px auto !important; text-align:center; }}.claim { background-color:#fff4f4; border-left:4px solid #e63946; border-radius:10px; padding:20px 24px; margin:24px 0; font-family:system-ui,sans-serif; line-height:1.6; position:relative; box-shadow:0 2px 6px rgba(0,0,0,0.03); }.claim-true { background-color:#eafaf0; border-left-color:#2ecc71; }.claim-icon { display:inline-block; font-size:18px; color:#e63946; margin-right:10px; vertical-align:middle; }.claim-true .claim-icon { color:#2ecc71; }.claim-title { display:flex; align-items:center; font-weight:600; font-size:16px; color:#222; }.claim-label { margin-left:auto; font-size:12px; background-color:#e63946; color:#fff; padding:3px 10px; border-radius:12px; font-weight:bold; }.claim-true .claim-label { background-color:#2ecc71; }.claim-explanation { margin-top:8px; color:#555; font-size:15px; }.claim-pair { margin:32px 0; }<\/style>\n<p style=\"float: right; margin-left: 15px; margin-bottom: 15px;\">\n  <img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/glowinled.com\/wp-content\/uploads\/2026\/01\/v2-article-1769340396118-2.jpg\" alt=\"LM-80 test report verification for LED strips\" class=\"top-image-square\">\n<\/p>\n<p>Every week, our team reviews <a href=\"https:\/\/vertexaisearch.cloud.google.com\/grounding-api-redirect\/AUZIYQFVvab20CJiBU2FmTMgMyW57NflnwBYmHrLyHenjkOK6zkA3PsXObSrCX-kuYQudCENchHSFvjwVggK8-QUNGuGjd11-QdZQYmKURFzoA_Taa-w0hcB4ZtXTWOX9K00ZsvENTTBsLicBF_2xTxUJW9Nk2pxPUBir7RJpqatafeIFdda48Xh9MVOMHJpfg==\" target=\"_blank\" rel=\"noopener noreferrer\">LM-80 reports<\/a> <sup id=\"ref-1\"><a href=\"#footnote-1\" class=\"footnote-ref\">1<\/a><\/sup> from LED chip suppliers before we commit to any production run \u2014 and we've seen everything from pristine original documents to suspiciously vague one-page summaries.<\/p>\n<p><strong>To verify an LM-80 report, confirm it originates from the LED chip manufacturer, check that the testing lab holds recognized accreditation (such as NVLAP or CNAS), ensure the test ran at least 6,000 hours across multiple case temperatures, and review the raw lumen and color maintenance data \u2014 not just a summary statement.<\/strong><\/p>\n<p>This guide walks you through exactly what to check, what red flags to watch for, and how to use LM-80 data to protect your lighting project from long-term failures <a href=\"https:\/\/www.nist.gov\/nvlap\" target=\"_blank\" rel=\"noopener noreferrer\">recognized accreditation<\/a> <sup id=\"ref-2\"><a href=\"#footnote-2\" class=\"footnote-ref\">2<\/a><\/sup>. Let's start with the basics of authentication.<\/p>\n<h2>How can I verify that the LM-80 report provided by my LED supplier is authentic and up to date?<\/h2>\n<p>We have rejected suppliers in the past simply because they could not produce an original, unedited LM-80 report \u2014 and that single check saved our clients from installing subpar LED strips on a major hotel project <a href=\"https:\/\/vertexaisearch.cloud.google.com\/grounding-api-redirect\/AUZIYQGWM4R6UwGhxhOtkA2580t0tGw7_c1s-r_sRpARJYtdhEIuhuU4sLUuJr7zwFxbAUkbinCsYO60_zYR79sA_ERsXmxVwD-H_OA1yPH3qldxAJ1IYzXbf4px\" target=\"_blank\" rel=\"noopener noreferrer\">DLC listings<\/a> <sup id=\"ref-3\"><a href=\"#footnote-3\" class=\"footnote-ref\">3<\/a><\/sup>.<\/p>\n<p><strong>Verify authenticity by matching the LED model and bin codes on the report to your actual product, confirming the testing laboratory's accreditation on official directories like NVLAP or EPA's recognized lab list, and checking the report issue date is within a reasonable timeframe for the product generation.<\/strong><\/p>\n<h3>Start With the Source: Who Issued the Report?<\/h3>\n<p>An LM-80 report should come from the LED chip or package manufacturer \u2014 companies like Lumileds, Samsung, Cree, or Osram <a href=\"https:\/\/vertexaisearch.cloud.google.com\/grounding-api-redirect\/AUZIYQHtpHyrYzFGAAOQXAsapiu3F85ab2TY6C1Jf7lLsaq-cz9EiMpcrj4-5MCla5IQl6O7Cpp-qitRw5z3y7SwnpaQC67rf7ipzNM5lUTwsN4bdFGzDfIOE3Qb1F1lTHpPeq6b1UH5Z1_32VFnD3zzRxphjtzGjNk3Ja04BBKqfQKMP_IfwWs=\" target=\"_blank\" rel=\"noopener noreferrer\">chromaticity shift data (\u0394u'v')<\/a> <sup id=\"ref-4\"><a href=\"#footnote-4\" class=\"footnote-ref\">4<\/a><\/sup>. <a href=\"https:\/\/vertexaisearch.cloud.google.com\/grounding-api-redirect\/AUZIYQHltYAkKsd8i6Mt7ktjkWD5WyNuTVQXkLLO625BUCPBQIRthfR3cyGqLz7UQt_flnU4eSv_P6beEVnxx8Qpk9-vZsP_t8-KJ34o5mks7bvvg4Cwiyb_MDcYHhmfYpYHH7yK7IY3iSU3_qWcIum57Atk7oPDkV2fsTM=\" target=\"_blank\" rel=\"noopener noreferrer\">LED chip manufacturer<\/a> <sup id=\"ref-5\"><a href=\"#footnote-5\" class=\"footnote-ref\">5<\/a><\/sup> It is not something a strip assembler generates. When our engineering team receives a report, the first thing we check is the header <a href=\"https:\/\/vertexaisearch.cloud.google.com\/grounding-api-redirect\/AUZIYQG7yQcf2v4P7wWgfeHYzxCGFdhV64N00lN93St47Ghghy3qKShqkJhPMA1yT134WJIh6IBQFy5w1GCb_5mdCUuB0vFrE_3DrHUxGAwiO8OWXPXvG4V0Vz8i61KXyCDZaAvybv7PV_0RKx2lg3GLfPaw\" target=\"_blank\" rel=\"noopener noreferrer\">TM-21 extrapolation<\/a> <sup id=\"ref-6\"><a href=\"#footnote-6\" class=\"footnote-ref\">6<\/a><\/sup>. The report must name the chip manufacturer and the accredited lab that performed the testing.<\/p>\n<p>If your supplier hands you a report with their own company logo on it and no reference to a recognized test lab, that's a red flag. The report is either a copy with modifications or a self-generated summary \u2014 neither of which holds value for certification.<\/p>\n<h3>Check Lab Accreditation<\/h3>\n<p>The testing laboratory must be accredited. For projects targeting <a href=\"https:\/\/vertexaisearch.cloud.google.com\/grounding-api-redirect\/AUZIYQFYeDRlnR5Hm43445a7s7cv1PzjWCHUP-qQyuEpFr3hrGAeqMlwwkPsf8u_WY3Ro_fCVHhVPtIDP_DS7SwVQuZoE_lZfEL3edfc-TaivpWzL6aabQAAQUErhX-caMSqzw-0cPQWAKGIHLxoOszx5MSR-MpmDR0OoU2AKOCMAXzQfvW3sXri\" target=\"_blank\" rel=\"noopener noreferrer\">ENERGY STAR<\/a> <sup id=\"ref-7\"><a href=\"#footnote-7\" class=\"footnote-ref\">7<\/a><\/sup> or DLC listings, the lab needs to appear on the EPA's recognized laboratory list. For international projects, look for accreditation from bodies like <a href=\"https:\/\/vertexaisearch.cloud.google.com\/grounding-api-redirect\/AUZIYQHZrRsfFAvJ-oSkedwFKrwfOWXc3iBvrhu6DxKp8VIvPNH9lsRkzxISLAEQPGA3Zn1CKSsltf-Q7reKsojJWUVTkuoVeCc_o6glZAfnd4V1PWqTmAj1\" target=\"_blank\" rel=\"noopener noreferrer\">NVLAP<\/a> <sup id=\"ref-8\"><a href=\"#footnote-8\" class=\"footnote-ref\">8<\/a><\/sup>, A2LA, CNAS, or ILAC member organizations.<\/p>\n<p>You can verify accreditation online. NVLAP maintains a searchable directory. <a href=\"http:\/\/www.cnas.org.cn\/\" target=\"_blank\" rel=\"noopener noreferrer\">CNAS<\/a> <sup id=\"ref-9\"><a href=\"#footnote-9\" class=\"footnote-ref\">9<\/a><\/sup> has one too. If the lab name on the report does not appear in any accredited directory, the report is unreliable.<\/p>\n<h3>Match the Product Details<\/h3>\n<p>The report must match the exact LED package you are using. This means verifying:<\/p>\n<ul>\n<li>LED model number<\/li>\n<li>Color temperature (CCT)<\/li>\n<li>Drive current<\/li>\n<li>Bin code or lot information<\/li>\n<\/ul>\n<p>A report for a 3000K LED does not validate a 5000K variant. A report tested at 350mA does not cover a strip running at 700mA.<\/p>\n<h3>Confirm the Test Duration and Date<\/h3>\n<p>LM-80-20 requires a minimum of <a href=\"https:\/\/vertexaisearch.cloud.google.com\/grounding-api-redirect\/AUZIYQHqZi5WuqGjd5q3-sUGS4-B268oAU-Ho_S6ZSGLJRBlwiKrZyhZQOsw5iH39yAGtx83znjdLqd4QDR0xbuMeOpj0ZyD_31RTqIi0jDnQkwAG0lycYskBWmMdj0Qt7V2lYA0pwhH5XY7JYx-YQs_xHbW8TpvVxSuHxxvLUEfrZ1pTWzOeJ6NMWq8Op-xEKm0Ly5t\" target=\"_blank\" rel=\"noopener noreferrer\">6,000 hours<\/a> <sup id=\"ref-10\"><a href=\"#footnote-10\" class=\"footnote-ref\">10<\/a><\/sup> of testing. Many premium chip makers now test to 10,000 hours or beyond. Check the test initiation date and the report issue date. If a report is older than five years, ask whether the chip generation has changed. Older reports may still be technically valid, but they may not reflect current manufacturing processes.<\/p>\n<table>\n<thead>\n<tr>\n<th>Verification Item<\/th>\n<th>What to Check<\/th>\n<th>Where to Confirm<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Testing Lab<\/td>\n<td>Lab name and accreditation number<\/td>\n<td>NVLAP, CNAS, or EPA lab directory<\/td>\n<\/tr>\n<tr>\n<td>LED Package<\/td>\n<td>Model number, CCT, drive current<\/td>\n<td>Compare to your BOM or supplier spec sheet<\/td>\n<\/tr>\n<tr>\n<td>Test Duration<\/td>\n<td>Minimum 6,000 hours<\/td>\n<td>Look for data points at 1k, 2k, 3k, 4k, 6k hrs<\/td>\n<\/tr>\n<tr>\n<td>Report Date<\/td>\n<td>Issue date vs. product generation<\/td>\n<td>Ask supplier for production date of chips<\/td>\n<\/tr>\n<tr>\n<td>Raw Data<\/td>\n<td>Full tables and graphs, not summaries<\/td>\n<td>Request complete report, not excerpts<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Watch for Common Red Flags<\/h3>\n<p>Some suppliers provide a one-page \"LM-80 certificate\" with a single line saying the product \"complies with LM-80.\" This tells you nothing. A real LM-80 report is often over 100 pages. It contains raw measurement data at every 1,000-hour interval, for every temperature subset, for every sample.<\/p>\n<p>If the report is short, lacks data tables, or does not specify test temperatures, do not accept it. Ask for the full original file \u2014 ideally a PDF directly from the chip manufacturer.<\/p>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> A genuine LM-80 report is issued by the LED chip or package manufacturer, not by the LED strip assembler. <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">LM-80 testing applies to LED packages, arrays, or modules at the component level. Strip assemblers use these reports but do not generate them.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> A one-page summary stating \"complies with LM-80\" is sufficient proof for certification submissions. <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">Certification bodies like DLC and ENERGY STAR require the full LM-80 report with raw data, lab accreditation details, and complete test conditions \u2014 not a summary or certificate.<\/div>\n<\/div>\n<\/div>\n<h2>What specific technical metrics should I look for in the report to ensure my LED strips maintain color consistency?<\/h2>\n<p>On our production lines, we test every reel of LED strip for color consistency before shipment \u2014 but that final-step QC only works if the upstream LED chip data is solid, and that starts with reading the LM-80 report correctly.<\/p>\n<p><strong>Focus on chromaticity shift data (\u0394u'v') reported at each temperature and time interval. The LM-80 report tracks changes in color coordinates over thousands of hours, and any shift exceeding 0.007 \u0394u'v' signals potential visible color drift that can ruin architectural lighting uniformity.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/glowinled.com\/wp-content\/uploads\/2026\/01\/High-density-cob-led-strip.webp\" alt=\"LED strip color consistency metrics in LM-80 report\"><\/p>\n<h3>Understanding Chromaticity Maintenance Data<\/h3>\n<p>LM-80 does not only measure brightness. It also tracks color shift over time. The report records chromaticity coordinates (u', v') at every measurement interval \u2014 typically every 1,000 hours. The shift is expressed as \u0394u'v', which is the total change from the initial color point.<\/p>\n<p>For architectural projects \u2014 cove lighting, facade illumination, hospitality interiors \u2014 even a small color shift becomes visible when strips are installed side by side over long runs. A \u0394u'v' above 0.007 is generally considered noticeable to the human eye.<\/p>\n<h3>Key Color Metrics in the Report<\/h3>\n<p>When reviewing the LM-80 report for color data, look for these specific items:<\/p>\n<table>\n<thead>\n<tr>\n<th>Metric<\/th>\n<th>What It Tells You<\/th>\n<th>Acceptable Range<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Initial chromaticity (u', v')<\/td>\n<td>Starting color point of the LED<\/td>\n<td>Should match your target CCT bin<\/td>\n<\/tr>\n<tr>\n<td>\u0394u'v' at 6,000 hours<\/td>\n<td>Total color shift after test period<\/td>\n<td>&lt; 0.007 for most architectural applications<\/td>\n<\/tr>\n<tr>\n<td>\u0394u'v' at highest temperature<\/td>\n<td>Worst-case color shift scenario<\/td>\n<td>Lower is better; compare across temps<\/td>\n<\/tr>\n<tr>\n<td>Color maintenance curve<\/td>\n<td>Trend of shift over time<\/td>\n<td>Should be stable, not accelerating<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Why Temperature Matters for Color<\/h3>\n<p>The LM-80 standard requires testing at a minimum of three case temperatures \u2014 typically 55\u00b0C, 85\u00b0C, and one additional temperature chosen by the manufacturer. Color shift tends to worsen at higher temperatures. This matters because the actual operating temperature of your LED strip inside an aluminum channel or behind a diffuser may be significantly higher than room temperature.<\/p>\n<p>When we design custom strips for enclosed installations \u2014 like recessed profiles or outdoor IP67 extrusions \u2014 we pay close attention to the 85\u00b0C data set. If the chromaticity shift is already trending upward at 85\u00b0C after 6,000 hours, the LEDs may exhibit visible color change within two to three years in a real-world enclosed application.<\/p>\n<h3>Drive Current: The Hidden Variable<\/h3>\n<p>The LM-80 report tests LEDs at a specific drive current. If your LED strip operates at a higher current than what was tested, both lumen depreciation and color shift will accelerate. Always cross-reference the drive current listed in the LM-80 report with the actual operating current in your strip design.<\/p>\n<p>For example, if the report tests at 65mA per LED and your strip drives each LED at 80mA, the LM-80 data underestimates degradation. This is a common oversight \u2014 and one we flag during our design review process with clients who request custom current configurations.<\/p>\n<h3>Don't Ignore the Raw Data<\/h3>\n<p>Some suppliers provide only averaged data or summary graphs. This can mask outliers. If one sample out of twenty shows rapid color drift, an average graph may hide that. Request the raw data tables. Look at individual sample readings. Consistency across samples matters as much as the average result.<\/p>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> A \u0394u'v' shift exceeding 0.007 in the LM-80 chromaticity data indicates a potentially visible color change in the LED over its tested duration. <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">Industry consensus and standards like ENERGY STAR use 0.007 \u0394u'v' as the threshold for perceptible chromaticity shift, which is critical for color-sensitive applications.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> LM-80 only measures lumen depreciation and does not include any color or chromaticity data. <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">LM-80-20 explicitly requires measurement and reporting of chromaticity coordinates (u', v') at each test interval alongside luminous flux data, covering both lumen and color maintenance.<\/div>\n<\/div>\n<\/div>\n<h2>How does the lumen maintenance data in the LM-80 report impact the long-term performance of my custom lighting project?<\/h2>\n<p>When we help clients spec out LED strips for five-year or ten-year project lifecycles, the conversation always comes back to one question: how much light will these LEDs lose over time? The LM-80 report is where the answer begins.<\/p>\n<p><strong>Lumen maintenance data from LM-80 shows the percentage of original light output retained over thousands of hours at specific temperatures. Combined with TM-21 extrapolation, this data predicts when LEDs will drop below acceptable brightness levels, directly influencing your project's maintenance schedule and total cost of ownership.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/glowinled.com\/wp-content\/uploads\/2026\/02\/v2-article-1770359554045-3.jpg\" alt=\"Lumen maintenance curve from LM-80 report for LED project planning\"><\/p>\n<h3>What Lumen Maintenance Actually Means<\/h3>\n<p>Lumen maintenance is expressed as a ratio: current lumens divided by initial lumens. A value of 0.95 at 6,000 hours means the LED retains 95% of its original brightness at the tested temperature after 6,000 hours of operation. This metric is reported for each temperature subset in the LM-80 report.<\/p>\n<p>For project planning, the industry commonly references L70 \u2014 the point at which an LED retains 70% of its initial output. Most commercial and architectural specifications consider L70 to be the practical end of useful life. But LM-80 itself does not predict L70. That projection comes from TM-21.<\/p>\n<h3>How LM-80 and TM-21 Work Together<\/h3>\n<p>LM-80 provides the raw data. TM-21 is the mathematical standard that extrapolates that data to project future performance. If the LM-80 report shows steady, predictable decay over 6,000 or 10,000 hours, TM-21 can project an L70 lifetime \u2014 but only up to 6 times the test duration.<\/p>\n<p>So if your LM-80 test ran for 10,000 hours, TM-21 can project up to 60,000 hours. This is a critical point: the longer the LM-80 test, the further TM-21 can project. This is why we always prefer working with chip suppliers who test to 10,000 hours or more.<\/p>\n<h3>Temperature and Lumen Life: The Real-World Connection<\/h3>\n<p>Here's where LM-80 data becomes directly actionable. The report provides lumen maintenance data at multiple temperatures. Higher temperatures always produce faster depreciation.<\/p>\n<table>\n<thead>\n<tr>\n<th>Case Temperature<\/th>\n<th>Lumen Maintenance at 6,000 hrs<\/th>\n<th>Projected L70 (via TM-21)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>55\u00b0C<\/td>\n<td>97.5%<\/td>\n<td>&gt; 60,000 hours<\/td>\n<\/tr>\n<tr>\n<td>85\u00b0C<\/td>\n<td>94.2%<\/td>\n<td>~50,000 hours<\/td>\n<\/tr>\n<tr>\n<td>105\u00b0C (custom)<\/td>\n<td>90.1%<\/td>\n<td>~36,000 hours<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These numbers are illustrative but reflect real-world patterns. The difference between 55\u00b0C and 105\u00b0C can cut projected lifetime nearly in half. For our clients installing strips in tight aluminum profiles or behind decorative panels, we always recommend checking the higher-temperature dataset \u2014 because that's closer to real operating conditions.<\/p>\n<h3>In-Situ Temperature: Bridging the Gap<\/h3>\n<p>LM-80 tests LED packages in controlled lab conditions. Your actual luminaire has heat sinks, drivers, ambient temperatures, and airflow characteristics that the lab did not replicate. This is where in-situ temperature measurement (ISTMT) becomes important.<\/p>\n<p>DLC, for example, now requires TMP_LED photos showing the actual LED case temperature inside the finished luminaire. If your strip runs at a case temperature of 75\u00b0C inside its profile, you should reference the LM-80 data closest to that temperature \u2014 typically the 85\u00b0C dataset \u2014 for a conservative estimate.<\/p>\n<h3>Planning Maintenance and Replacements<\/h3>\n<p>For a five-year project, an LED with L70 at 60,000 hours is likely fine \u2014 it will retain roughly 90% of its brightness by year five (assuming typical operating hours). But for a ten-year specification, you need to dig deeper. Request TM-21 calculations from your supplier. Ask which temperature dataset they used. If they used the 55\u00b0C data but your strip runs hotter, their claim overstates the real performance.<\/p>\n<p>We've seen projects where the original specification promised 50,000-hour L70, but the actual installation temperatures pushed effective L70 down to 30,000 hours. That's a costly re-lamping cycle that nobody budgeted for. Reading the LM-80 report carefully \u2014 and matching it to your real conditions \u2014 prevents this.<\/p>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> TM-21 can only project LED lifetime up to 6 times the duration of the LM-80 test data used for extrapolation. <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">The TM-21 standard limits extrapolation to 6\u00d7 the tested hours to maintain statistical validity, which is why longer LM-80 test durations yield more useful lifetime projections.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> LM-80 data tested at 55\u00b0C accurately predicts LED performance in enclosed luminaire installations that run at 85\u00b0C or higher. <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">Lumen depreciation accelerates significantly at higher temperatures. Using low-temperature LM-80 data to predict performance in high-temperature applications will overestimate lifespan and understate lumen loss.<\/div>\n<\/div>\n<\/div>\n<h2>Can I rely on my supplier's LM-80 report to meet the strict certification requirements for my project bidding?<\/h2>\n<p>Our clients in Australia and Germany regularly submit lighting documentation for project approvals, and we've learned the hard way that a technically valid LM-80 report can still be rejected if it doesn't meet the specific format and accreditation requirements of the certifying body.<\/p>\n<p><strong>You can use your supplier's LM-80 report for certification if it comes from an accredited lab recognized by the relevant program (ENERGY STAR, DLC, or local standards), covers the exact LED component in your product, includes complete raw data at all required temperature subsets, and is supplemented with a valid TM-21 projection.<\/strong><\/p>\n<p><img decoding=\"async\" style=\"max-width:100%; height:auto;\" src=\"https:\/\/glowinled.com\/wp-content\/uploads\/2026\/01\/v2-article-1769340396876-3.jpg\" alt=\"LM-80 report certification requirements for LED project bidding\"><\/p>\n<h3>Certification Bodies Have Specific Requirements<\/h3>\n<p>Different programs have different rules. DLC requires LM-80 reports from labs on their accepted list. ENERGY STAR has its own recognized laboratory directory. If your project targets a specific green building rating or government procurement standard, check which certifications are needed first \u2014 then verify the LM-80 report meets those exact requirements.<\/p>\n<h3>What Certification Reviewers Actually Check<\/h3>\n<p>When a DLC or ENERGY STAR reviewer evaluates your application, they don't just glance at the report. They examine:<\/p>\n<ul>\n<li>Lab accreditation status at the time of testing<\/li>\n<li>LED model number match to your product listing<\/li>\n<li>Complete data tables (not summaries)<\/li>\n<li>Temperature subsets (at least three)<\/li>\n<li>Test duration (minimum 6,000 hours)<\/li>\n<li>Chromaticity data alongside lumen data<\/li>\n<li>TM-21 report as a separate supplemental document<\/li>\n<\/ul>\n<p>If any of these items are missing, your application gets rejected or delayed. We've seen clients lose bidding deadlines because their supplier provided an incomplete LM-80 package.<\/p>\n<h3>The Grandfathering Issue<\/h3>\n<p>Older LM-80 reports \u2014 those generated under LM-80-08 rather than LM-80-15 or LM-80-20 \u2014 may or may not be accepted depending on the program. ENERGY STAR has periodically updated its requirements and set cutoff dates for older report formats. Always confirm with the certifying body whether the report version is still accepted.<\/p>\n<h3>Common Reasons for Certification Rejection<\/h3>\n<table>\n<thead>\n<tr>\n<th>Rejection Reason<\/th>\n<th>How to Prevent It<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Lab not on recognized list<\/td>\n<td>Verify lab accreditation before ordering chips<\/td>\n<\/tr>\n<tr>\n<td>LED model mismatch<\/td>\n<td>Cross-check LM-80 report model with your BOM<\/td>\n<\/tr>\n<tr>\n<td>Missing chromaticity data<\/td>\n<td>Request full report, not just lumen data<\/td>\n<\/tr>\n<tr>\n<td>No TM-21 supplement<\/td>\n<td>Ask chip manufacturer for TM-21 calculation<\/td>\n<\/tr>\n<tr>\n<td>Test duration under 6,000 hours<\/td>\n<td>Reject any report with less than 6,000 hours<\/td>\n<\/tr>\n<tr>\n<td>Outdated report version (LM-80-08)<\/td>\n<td>Confirm program accepts the report revision<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Practical Steps Before You Bid<\/h3>\n<p>Before you submit your bid, create a documentation package that includes:<\/p>\n<ol>\n<li>The original LM-80 report (full PDF, not excerpts)<\/li>\n<li>A TM-21 calculation report referencing the LM-80 data<\/li>\n<li>Lab accreditation certificate or link to the accreditation directory listing<\/li>\n<li>A product traceability document linking the LED chip model in the report to the exact LED strip model in your bid<\/li>\n<\/ol>\n<p>When we prepare documentation for our clients, we compile all four items and review them against the target certification's checklist. This proactive approach has helped our partners win bids in competitive markets like Germany and Australia where documentation rigor is high.<\/p>\n<h3>The Bigger Picture: LM-80 Is Necessary But Not Sufficient<\/h3>\n<p>An LM-80 report covers the LED component \u2014 not the finished luminaire. For a complete certification package, you may also need LM-79 testing on the finished LED strip or luminaire, which measures total luminous flux, efficacy, color rendering, and power consumption at the product level. LM-80 and LM-79 serve complementary roles: LM-80 validates the LED component's longevity, while LM-79 validates the finished product's photometric performance.<\/p>\n<p>If your project requires both, make sure your supplier can provide or facilitate both reports. Some testing labs offer bundled services, and working with a supplier who understands the full documentation chain \u2014 as we do for our OEM partners \u2014 saves significant time and avoids costly resubmissions.<\/p>\n<div class=\"claim-pair\">\n<div class=\"claim claim-true\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2714<\/span> Certification programs like DLC and ENERGY STAR require LM-80 reports from labs on their specific recognized or accepted laboratory lists. <span class=\"claim-label\">True<\/span><\/div>\n<div class=\"claim-explanation\">Both DLC and ENERGY STAR maintain directories of approved testing labs, and reports from non-recognized labs are routinely rejected during the application review process.<\/div>\n<\/div>\n<div class=\"claim claim-false\">\n<div class=\"claim-title\"><span class=\"claim-icon\">\u2718<\/span> An LM-80 report alone is enough to certify a finished LED strip or luminaire for ENERGY STAR or DLC listing. <span class=\"claim-label\">False<\/span><\/div>\n<div class=\"claim-explanation\">LM-80 only covers the LED component. Finished product certification also requires LM-79 photometric testing, TM-21 projections, and additional documentation specific to the luminaire.<\/div>\n<\/div>\n<\/div>\n<h2>Conclusion<\/h2>\n<p>Verifying an LM-80 report takes effort, but it protects your project from premature failures, certification rejections, and costly surprises. Demand the full original report, check every detail, and never settle for a summary.<\/p>\n<h2>Footnotes<\/h2>\n<p><span id=\"footnote-1\"><\/p>\n<ol>\n<li>Explains the IES LM-80 standard for measuring LED lumen maintenance. <a href=\"#ref-1\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-2\"><\/p>\n<ol start=\"2\">\n<li>Found an authoritative government source (NIST) for NVLAP, which is a recognized accreditation body for testing laboratories. <a href=\"#ref-2\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-3\"><\/p>\n<ol start=\"3\">\n<li>Provides access to the DesignLights Consortium Qualified Products List. <a href=\"#ref-3\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-4\"><\/p>\n<ol start=\"4\">\n<li>Explains the CIE 1976 (u',v') chromaticity diagram and \u0394u'v'. <a href=\"#ref-4\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-5\"><\/p>\n<ol start=\"5\">\n<li>Provides an overview of companies manufacturing LED chips. <a href=\"#ref-5\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-6\"><\/p>\n<ol start=\"6\">\n<li>Official IES page for the TM-21 standard on lumen maintenance projections. <a href=\"#ref-6\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-7\"><\/p>\n<ol start=\"7\">\n<li>Provides information on ENERGY STAR certified lighting products. <a href=\"#ref-7\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-8\"><\/p>\n<ol start=\"8\">\n<li>Official site for the National Voluntary Laboratory Accreditation Program. <a href=\"#ref-8\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-9\"><\/p>\n<ol start=\"9\">\n<li>Found the official website for the China National Accreditation Service for Conformity Assessment (CNAS). <a href=\"#ref-9\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><span id=\"footnote-10\"><\/p>\n<ol start=\"10\">\n<li>Confirms the minimum test duration requirement for LM-80. <a href=\"#ref-10\" class=\"footnote-backref\">\u21a9\ufe0e<\/a><br \/>\n<\/span><\/li>\n<\/ol>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How to Verify the LM-80 Test Report From Your Supplier?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"To verify an LM-80 report, confirm it originates from the LED chip manufacturer, check that the testing lab holds recognized accreditation (such as NVLAP or CNAS), ensure the test ran at least 6,000 hours across multiple case temperatures, and review the raw lumen and color maintenance data &mdash; not just a summary statement.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How can I verify that the LM-80 report provided by my LED supplier is authentic and up to date?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Verify authenticity by matching the LED model and bin codes on the report to your actual product, confirming the testing laboratory's accreditation on official directories like NVLAP or EPA's recognized lab list, and checking the report issue date is within a reasonable timeframe for the product generation.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What specific technical metrics should I look for in the report to ensure my LED strips maintain color consistency?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Focus on chromaticity shift data (&Delta;u'v') reported at each temperature and time interval. The LM-80 report tracks changes in color coordinates over thousands of hours, and any shift exceeding 0.007 &Delta;u'v' signals potential visible color drift that can ruin architectural lighting uniformity.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How does the lumen maintenance data in the LM-80 report impact the long-term performance of my custom lighting project?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Lumen maintenance data from LM-80 shows the percentage of original light output retained over thousands of hours at specific temperatures. Combined with TM-21 extrapolation, this data predicts when LEDs will drop below acceptable brightness levels, directly influencing your project's maintenance schedule and total cost of ownership.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I rely on my supplier's LM-80 report to meet the strict certification requirements for my project bidding?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"You can use your supplier's LM-80 report for certification if it comes from an accredited lab recognized by the relevant program (ENERGY STAR, DLC, or local standards), covers the exact LED component in your product, includes complete raw data at all required temperature subsets, and is supplemented with a valid TM-21 projection.\"\n      }\n    }\n  ]\n}\n<\/script><br \/>\n<script type=\"application\/ld+json\">\n[\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"A genuine LM-80 report is issued by the LED chip or package manufacturer, not by the LED strip assembler.\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"A one-page summary stating \\\"complies with LM-80\\\" is sufficient proof for certification submissions.\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"A &Delta;u'v' shift exceeding 0.007 in the LM-80 chromaticity data indicates a potentially visible color change in the LED over its tested duration.\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"LM-80 only measures lumen depreciation and does not include any color or chromaticity data.\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"TM-21 can only project LED lifetime up to 6 times the duration of the LM-80 test data used for extrapolation.\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"LM-80 data tested at 55&deg;C accurately predicts LED performance in enclosed luminaire installations that run at 85&deg;C or higher.\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"Certification programs like DLC and ENERGY STAR require LM-80 reports from labs on their specific recognized or accepted laboratory lists.\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 5,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"True\"\n    }\n  },\n  {\n    \"@context\": \"https:\/\/schema.org\",\n    \"@type\": \"ClaimReview\",\n    \"url\": \"\",\n    \"claimReviewed\": \"An LM-80 report alone is enough to certify a finished LED strip or luminaire for ENERGY STAR or DLC listing.\",\n    \"author\": {\n      \"@type\": \"Organization\",\n      \"name\": \"Article Author\"\n    },\n    \"reviewRating\": {\n      \"@type\": \"Rating\",\n      \"ratingValue\": 1,\n      \"bestRating\": 5,\n      \"worstRating\": 1,\n      \"alternateName\": \"False\"\n    }\n  }\n]\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u0414\u043b\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0438 \u043e\u0442\u0447\u0435\u0442\u0430 LM-80 \u0443\u0431\u0435\u0434\u0438\u0442\u0435\u0441\u044c, \u0447\u0442\u043e \u043e\u043d \u0438\u0441\u0445\u043e\u0434\u0438\u0442 \u043e\u0442 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044f \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u0447\u0438\u043f\u043e\u0432, \u043f\u0440\u043e\u0432\u0435\u0440\u044c\u0442\u0435 \u043d\u0430\u043b\u0438\u0447\u0438\u0435 \u0443 \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438, \u043f\u0440\u043e\u0432\u043e\u0434\u0438\u0432\u0448\u0435\u0439 \u0442\u0435\u0441\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435, \u043f\u0440\u0438\u0437\u043d\u0430\u043d\u043d\u043e\u0439 \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u0430\u0446\u0438\u0438 (\u043d\u0430\u043f\u0440\u0438\u043c\u0435\u0440, NVLAP \u0438\u043b\u0438 \u2026<\/p>","protected":false},"author":1,"featured_media":1064,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[5,14],"tags":[],"class_list":["post-1417","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","category-cob-led-strip"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.5 (Yoast SEO v27.3) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How to Verify LM-80 Reports for LED Strips? - Custom LED Strip Manufacturer<\/title>\n<meta name=\"description\" content=\"Learn how to verify LM-80 reports for LED strips, including lab accreditation, TM-21 data, lumen maintenance, and color shift checks.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/glowinled.com\/ru\/how-to-verify-lm-80-reports-for-led-strips\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Verify LM-80 Reports for LED Strips?\" \/>\n<meta property=\"og:description\" content=\"Learn how to verify LM-80 reports for LED strips, including lab accreditation, TM-21 data, lumen maintenance, and color shift checks.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/glowinled.com\/ru\/how-to-verify-lm-80-reports-for-led-strips\/\" \/>\n<meta property=\"og:site_name\" content=\"Custom LED Strip Manufacturer\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-02T07:29:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/glowinled.com\/wp-content\/uploads\/2026\/01\/v2-article-1769340396118-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Elina\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elina\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f\" \/>\n\t<meta name=\"twitter:data2\" content=\"15 \u043c\u0438\u043d\u0443\u0442\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/\"},\"author\":{\"name\":\"Elina\",\"@id\":\"https:\\\/\\\/glowinled.com\\\/#\\\/schema\\\/person\\\/4e988063cf9726988d53ac539aab031a\"},\"headline\":\"How to Verify LM-80 Reports for LED Strips?\",\"datePublished\":\"2026-04-02T07:29:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/\"},\"wordCount\":2966,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/glowinled.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/glowinled.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/v2-article-1769340396118-2.jpg\",\"articleSection\":[\"Blog\",\"COB LED Strip\"],\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/\",\"url\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/\",\"name\":\"How to Verify LM-80 Reports for LED Strips? - Custom LED Strip Manufacturer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/glowinled.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/glowinled.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/v2-article-1769340396118-2.jpg\",\"datePublished\":\"2026-04-02T07:29:30+00:00\",\"description\":\"Learn how to verify LM-80 reports for LED strips, including lab accreditation, TM-21 data, lumen maintenance, and color shift checks.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/#primaryimage\",\"url\":\"https:\\\/\\\/glowinled.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/v2-article-1769340396118-2.jpg\",\"contentUrl\":\"https:\\\/\\\/glowinled.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/v2-article-1769340396118-2.jpg\",\"width\":600,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/glowinled.com\\\/how-to-verify-lm-80-reports-for-led-strips\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/glowinled.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Verify LM-80 Reports for LED Strips?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/glowinled.com\\\/#website\",\"url\":\"https:\\\/\\\/glowinled.com\\\/\",\"name\":\"Custom LED Strip Manufacturer\",\"description\":\"GLOWIN LED\",\"publisher\":{\"@id\":\"https:\\\/\\\/glowinled.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/glowinled.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/glowinled.com\\\/#organization\",\"name\":\"Glowin\",\"url\":\"https:\\\/\\\/glowinled.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/glowinled.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/glowinled.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Glowin-logo-350-100px.webp\",\"contentUrl\":\"https:\\\/\\\/glowinled.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Glowin-logo-350-100px.webp\",\"width\":350,\"height\":100,\"caption\":\"Glowin\"},\"image\":{\"@id\":\"https:\\\/\\\/glowinled.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/glowinled.com\\\/#\\\/schema\\\/person\\\/4e988063cf9726988d53ac539aab031a\",\"name\":\"Elina\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b01b8cac33403623fb37c0118840873d50ec4e4257cee93150088a6f4c5bdc41?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b01b8cac33403623fb37c0118840873d50ec4e4257cee93150088a6f4c5bdc41?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b01b8cac33403623fb37c0118840873d50ec4e4257cee93150088a6f4c5bdc41?s=96&d=mm&r=g\",\"caption\":\"Elina\"},\"sameAs\":[\"http:\\\/\\\/glowinled.com\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u041a\u0430\u043a \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043e\u0442\u0447\u0435\u0442\u044b LM-80 \u0434\u043b\u044f \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u043b\u0435\u043d\u0442? - \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u043b\u0435\u043d\u0442","description":"\u0423\u0437\u043d\u0430\u0439\u0442\u0435, \u043a\u0430\u043a \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043e\u0442\u0447\u0451\u0442\u044b LM-80 \u0434\u043b\u044f \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u043b\u0435\u043d\u0442, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u0430\u0446\u0438\u044e \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438, \u0434\u0430\u043d\u043d\u044b\u0435 TM-21, \u0441\u043e\u0445\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u044f\u0440\u043a\u043e\u0441\u0442\u0438 \u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0443 \u0446\u0432\u0435\u0442\u043e\u0432\u043e\u0433\u043e \u0441\u0434\u0432\u0438\u0433\u0430.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/glowinled.com\/ru\/how-to-verify-lm-80-reports-for-led-strips\/","og_locale":"ru_RU","og_type":"article","og_title":"How to Verify LM-80 Reports for LED Strips?","og_description":"Learn how to verify LM-80 reports for LED strips, including lab accreditation, TM-21 data, lumen maintenance, and color shift checks.","og_url":"https:\/\/glowinled.com\/ru\/how-to-verify-lm-80-reports-for-led-strips\/","og_site_name":"Custom LED Strip Manufacturer","article_published_time":"2026-04-02T07:29:30+00:00","og_image":[{"width":600,"height":400,"url":"https:\/\/glowinled.com\/wp-content\/uploads\/2026\/01\/v2-article-1769340396118-2.jpg","type":"image\/jpeg"}],"author":"Elina","twitter_card":"summary_large_image","twitter_misc":{"\u041d\u0430\u043f\u0438\u0441\u0430\u043d\u043e \u0430\u0432\u0442\u043e\u0440\u043e\u043c":"Elina","\u041f\u0440\u0438\u043c\u0435\u0440\u043d\u043e\u0435 \u0432\u0440\u0435\u043c\u044f \u0434\u043b\u044f \u0447\u0442\u0435\u043d\u0438\u044f":"15 \u043c\u0438\u043d\u0443\u0442"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/#article","isPartOf":{"@id":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/"},"author":{"name":"Elina","@id":"https:\/\/glowinled.com\/#\/schema\/person\/4e988063cf9726988d53ac539aab031a"},"headline":"How to Verify LM-80 Reports for LED Strips?","datePublished":"2026-04-02T07:29:30+00:00","mainEntityOfPage":{"@id":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/"},"wordCount":2966,"commentCount":0,"publisher":{"@id":"https:\/\/glowinled.com\/#organization"},"image":{"@id":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/#primaryimage"},"thumbnailUrl":"https:\/\/glowinled.com\/wp-content\/uploads\/2026\/01\/v2-article-1769340396118-2.jpg","articleSection":["Blog","COB LED Strip"],"inLanguage":"ru-RU","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/","url":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/","name":"\u041a\u0430\u043a \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043e\u0442\u0447\u0435\u0442\u044b LM-80 \u0434\u043b\u044f \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u043b\u0435\u043d\u0442? - \u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u0438\u043d\u0434\u0438\u0432\u0438\u0434\u0443\u0430\u043b\u044c\u043d\u044b\u0445 \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u043b\u0435\u043d\u0442","isPartOf":{"@id":"https:\/\/glowinled.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/#primaryimage"},"image":{"@id":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/#primaryimage"},"thumbnailUrl":"https:\/\/glowinled.com\/wp-content\/uploads\/2026\/01\/v2-article-1769340396118-2.jpg","datePublished":"2026-04-02T07:29:30+00:00","description":"\u0423\u0437\u043d\u0430\u0439\u0442\u0435, \u043a\u0430\u043a \u043f\u0440\u043e\u0432\u0435\u0440\u0438\u0442\u044c \u043e\u0442\u0447\u0451\u0442\u044b LM-80 \u0434\u043b\u044f \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u043b\u0435\u043d\u0442, \u0432\u043a\u043b\u044e\u0447\u0430\u044f \u0430\u043a\u043a\u0440\u0435\u0434\u0438\u0442\u0430\u0446\u0438\u044e \u043b\u0430\u0431\u043e\u0440\u0430\u0442\u043e\u0440\u0438\u0438, \u0434\u0430\u043d\u043d\u044b\u0435 TM-21, \u0441\u043e\u0445\u0440\u0430\u043d\u0435\u043d\u0438\u0435 \u044f\u0440\u043a\u043e\u0441\u0442\u0438 \u0438 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0443 \u0446\u0432\u0435\u0442\u043e\u0432\u043e\u0433\u043e \u0441\u0434\u0432\u0438\u0433\u0430.","breadcrumb":{"@id":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/#primaryimage","url":"https:\/\/glowinled.com\/wp-content\/uploads\/2026\/01\/v2-article-1769340396118-2.jpg","contentUrl":"https:\/\/glowinled.com\/wp-content\/uploads\/2026\/01\/v2-article-1769340396118-2.jpg","width":600,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/glowinled.com\/how-to-verify-lm-80-reports-for-led-strips\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/glowinled.com\/"},{"@type":"ListItem","position":2,"name":"How to Verify LM-80 Reports for LED Strips?"}]},{"@type":"WebSite","@id":"https:\/\/glowinled.com\/#website","url":"https:\/\/glowinled.com\/","name":"\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c \u043d\u0430 \u0437\u0430\u043a\u0430\u0437 \u0441\u0432\u0435\u0442\u043e\u0434\u0438\u043e\u0434\u043d\u044b\u0445 \u043b\u0435\u043d\u0442","description":"GLOWIN LED","publisher":{"@id":"https:\/\/glowinled.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/glowinled.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Organization","@id":"https:\/\/glowinled.com\/#organization","name":"\u0413\u043b\u043e\u0438\u043d","url":"https:\/\/glowinled.com\/","logo":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/glowinled.com\/#\/schema\/logo\/image\/","url":"https:\/\/glowinled.com\/wp-content\/uploads\/2025\/12\/Glowin-logo-350-100px.webp","contentUrl":"https:\/\/glowinled.com\/wp-content\/uploads\/2025\/12\/Glowin-logo-350-100px.webp","width":350,"height":100,"caption":"Glowin"},"image":{"@id":"https:\/\/glowinled.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/glowinled.com\/#\/schema\/person\/4e988063cf9726988d53ac539aab031a","name":"\u042d\u043b\u0438\u043d\u0430","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/b01b8cac33403623fb37c0118840873d50ec4e4257cee93150088a6f4c5bdc41?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b01b8cac33403623fb37c0118840873d50ec4e4257cee93150088a6f4c5bdc41?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b01b8cac33403623fb37c0118840873d50ec4e4257cee93150088a6f4c5bdc41?s=96&d=mm&r=g","caption":"Elina"},"sameAs":["http:\/\/glowinled.com"]}]}},"_links":{"self":[{"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/posts\/1417","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/comments?post=1417"}],"version-history":[{"count":1,"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/posts\/1417\/revisions"}],"predecessor-version":[{"id":1420,"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/posts\/1417\/revisions\/1420"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/media\/1064"}],"wp:attachment":[{"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/media?parent=1417"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/categories?post=1417"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/glowinled.com\/ru\/wp-json\/wp\/v2\/tags?post=1417"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}